PRODUCTS
|
Duplomatic Motion Solutions is an international corporation. Established player in the motion control market, the Group has been constantly growing for the last 6 years, increasing from one single facility to the present seven production sites, five of which are based in Italy, one in the U.S.A. With 330 employees, a turnover of over 80 million Euros and more than 1.000 customers all over the world, the Company is based in Parabiago, Milan.
Different models are available for the system needs.
This is requirement
Pressure Control Valves
Flow Control Valves
Locking valve
check valve
pressure reducer
Rabbit-Turtle Valves
Balance Valve,
pressure reducer valve
Multiple components can be combined with modular valves.
NG6, NG10,NG25 standards are available and product selection can be made according to flow requirement.
Regardless of product range,the maximum pressure ratio is in 320-350 bar range.
With pressure standard being standard, spring can be change in some models.)
(CETOP 2 ) NG 4 DIRECT OPERATED PRESSURE RELIEF VALVE ( PILOT OPERATED ) | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 2 | Position | Norm | (bar) | (lpm) |
PRM2-DT6/10N | AB Line | NG4 | 320 | 20 |
PRM2-PT6/10N | P Line | NG4 | 320 | 20 |
PRM2-BT6/10N | B Line | NG4 | 320 | 20 |
(CETOP 3 ) DIRECT OPERATED PRESSURE RELIEF VALVE | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 03 | Position | Norm | (bar) | (lpm) |
MCD4-SP/51N | P Line | NG6 | 150 | 50 |
MCD4-SAT/51N | A Line | NG6 | 150 | 50 |
MCD4-SBT/51N | B Line | NG6 | 150 | 50 |
MCD4-DT/51N | AB Line | NG6 | 150 | 50 |
MCD6-SP/51N | P Line | NG6 | 350 | 50 |
MCD6-SAT/51N | A Line | NG6 | 350 | 50 |
MCD6-SBT/51N | B Line | NG6 | 350 | 50 |
MCD6-DT/51N | AB Line | NG6 | 350 | 50 |
PBM3-SB4/10N/S | B Line | NG6 | 140 | 50 |
(CETOP 3 ) NG 6 MODULAR PRESSURE RELIEF VALVE ( PILOT OPERATED) | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 3 | Position | Norm | (bar) | (lpm) |
MRQ6-SP/51N | P Line | NG6 | 350 | 75 |
MRQ6-SAT/51N | A Line | NG6 | 350 | 75 |
MRQ6-SBT/51N | B Line | NG6 | 350 | 75 |
MRQ6-DT/51N | AB Line | NG6 | 350 | 75 |
(CETOP 5 ) NG 10 MODULAR PRESSURE RELIEF VALVE ( PILOT OPERATED) | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 05 | Position | Norm | (bar) | (lpm) |
PRM5-PT*/51 | P Line | NG10 | 320 | 100 |
PRM5-AT*/51 | A Line | NG10 | 320 | 100 |
PRM5-D*/51 | AB Line | NG10 | 320 | 100 |
PRM5-DT*/51 | AB Line | NG10 | 320 | 100 |
(CETOP 7) NG 16 MODULAR PRESSURE RELIEF VALVE ( PILOT OPERATED) | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 7 | Position | Norm | (bar) | (lpm) |
PRM7-PT6/10N/S | P Line | NG16 | 350 | 300 |
(CETOP 2-3-5-7) NG 4- NG 6-NG 10-NG 16 MODULAR DIRECT CHECK VALVE | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 2-3-5-7 | Position | Norm | (bar) | (lpm) |
CHM2-SA/10N | A Line | NG4 | 320 | 30 |
CHM2-SB/10N | B Line | NG4 | 320 | 30 |
CHM2-D/10N | A B Line | NG4 | 320 | 30 |
MVPP-SA/50 | A Line | NG6 | 350 | 50 |
MVPP-SB/50 | B Line | NG6 | 350 | 50 |
MVPP-D/50 | AB Line | NG6 | 350 | 50 |
CHM5-SA/10N | A Line | NG10 | 320 | 65 |
CHM5-SB/10N | B Line | NG10 | 320 | 65 |
CHM5-D/10N | AB Line | NG10 | 320 | 65 |
CHM7-SA/11N | A Line | NG16 | 350 | 300 |
CHM7-SB/11N | B Line | NG16 | 350 | 300 |
CHM7-D/11N | AB Line | NG16 | 350 | 300 |
(CETOP 3-5) NG 6-NG 10 MODULAR CHECK VALVE | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 3-5 | Position | Norm | (bar) | (lpm) |
MVR1-SP/51 | P Line | NG6 | 350 | 50 |
MVR1-SA/51 | A Line | NG6 | 350 | 50 |
MVR1-SB/51 | B Line | NG6 | 350 | 50 |
MVR1-ST/51 | T Line | NG6 | 350 | 50 |
MVR1-SPT/51 | PT Line | NG6 | 350 | 50 |
VR4M1-SP/50 | P Line | NG10 | 320 | 100 |
VR4M1-ST/50 | T Line | NG10 | 320 | 100 |
(CETOP 2-3-5-7) NG 4-NG 6-NG 10-NG 16 MODULAR FLOW RESTRICTOR VALVE | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 2-3-5-7 | Position | Norm | (bar) | (lpm) |
QTM2-SA/10N | A Line | NG4 | 320 | 30 |
QTM2-SB/10N | B Line | NG4 | 320 | 30 |
QTM2-D/10N | AB Line | NG4 | 320 | 30 |
MERS-SA/50 | A Line | NG6 | 350 | 50 |
MERS-SB/50 | B Line | NG6 | 350 | 50 |
MERS-D/50 | AB Line | NG6 | 350 | 50 |
MERS-GD/50 | AB Line | NG6 | 350 | 50 |
QTM5-SA/10N/S | A Line | NG10 | 320 | 80 |
QTM5-SB/10N/S | B Line | NG10 | 320 | 80 |
QTM5-D/10N/S | AB Line | NG10 | 320 | 80 |
QTM5-RD/10N/S | AB Line | NG10 | 320 | 80 |
QTM7-SA/10N/S | A Line | NG16 | 350 | 250 |
QTM7-D/10N/S | AB Line | NG16 | 350 | 250 |
(CETOP 3-5) NG 6-NG 10 FLOW CONTROL VALVES | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 3-5 | Position | Norm | (bar) | (lpm) |
RPC1-K/M/D * | AB Line | NG6 | 250 | 30 |
RPC1-K/M/P * | P Line | NG6 | 250 | 30 |
RPC1-K/4M/D * | AB Line | NG10 | 250 | 30 |
(CETOP 3-5-7) NG 6-NG 10-NG16 DIRECT OPERATED THREE-WAY PRESSURE REDUCING VALVE | ||||
Code | Control | Mounting | Min-Max Pressure | Max Flow |
CETOP 3-5-7 | Position | Norm | (bar) | (lpm) |
MZD5/RP/M/50 | P Line | NG6 | 50-280 | 50 |
MZD5/A/50 | A Line | NG6 | 50-280 | 50 |
MZD5/B/50 | B Line | NG6 | 50-280 | 50 |
Z4M6-I/50 | P Line | NG10 | 15-320 | 80 |
Z4M6-A/50 | A Line | NG10 | 15-320 | 80 |
Z4M6-B/50 | B Line | NG10 | 15-320 | 80 |
PZM7-P5/10N/S | P Line | NG16 | 15-250 | 250 |
PZM7-PA5/10N/S | A Line | NG16 | 15-250 | 250 |
(CETOP 3-5) NG 6-NG10 MODULAR VALVES | ||||
Code | Control | Mounting | Min-Max Pressure | Max Flow |
CETOP 3-5 | Position | Norm | (bar) | (lpm) |
MSD5/50 | P Line | NG6 | 50-280 | 50 |
SD4M5/50 | P Line | NG10 | 30-210 | 80 |
(CETOP 3-5-8) NG 6-NG10-NG25 MODULAR COMPENSATOR | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 3-5-8 | Position | Norm | (bar) | (lpm) |
PCM3-P8/10N | P Line | NG6 2 Yol | 350 | 40 |
PCM3-PT8/10N | P Line | NG6 3 Yol | 350 | 40 |
PCM5-P8/11N | P Line | NG10 2 Yol | 320 | 100 |
PCM5-PT8/11N | P Line | NG10 3 Yol | 320 | 100 |
PCM8-P8/EE/10N | P Line | NG25 2 Yol | 320 | 300 |
PCM8-PT8/EE/10N | P Line | NG25 3 Yol | 320 | 300 |
(CETOP 03) NG 6 MODULAR ELECTRIC FAST / SLOW SPEED SELECTION VALVE | ||||
Code | Control | Mounting | Max Pressure | Max Flow |
CETOP 03 | Position | Norm | (bar) | (lpm) |
RLM3A-A30/10ND24 | A Line | NG6 NO | 250 | 30 |
RLM3A-C30/10ND24 | A Line | NG6 NC | 250 | 30 |
RLM3T-A30/10ND24 | T Line | NG6 NO | 250 | 30 |
RLM3T-C30/10ND24 | T Line | NG6 NC | 250 | 30 |
SIX WAYS BANKABLE DIVERTER VALVES | |||||
Code | Drain Line | Voltage | Max Pressure | Max Flow | |
(bar) | (lpm) | ||||
BFD06-G038-TA6/10N-D24K1 | Internal Drain | 24 VDC | 250 | 60 | |
BFD06-G038-TA6/10N-D24K1/Y | External Drain | 24 VDC | 320 | 60 | |
BFD10-G012-TA6/10N-D24K1 | Internal Drain | 24 VDC | 250 | 90 | |
BFD10-G012-TA6/10N-D24K1/Y | External Drain | 24 VDC | 320 | 90 |
(CETOP 7-8-10) NG 16-NG 25-NG 32 PRESSURE RELIEF VALVES | |||||
Code | Control | Mounting | Max Pressure | Max Flow | |
CETOP 7-8-10 | Position | Norm | (bar) | (lpm) | |
RQ3-P6/41 | Manual | NG16 | 350 | 200 | |
RQ5-P6/41 | Manual | NG25 | 350 | 400 | |
RQ7-P6/41 | Manual | NG32 | 350 | 500 | |
RQM3-P6/A/60N | Electrical | NG16 | 350 | 200 | |
RQM5-P6/A/60N | Electrical | NG25 | 350 | 400 | |
RQM7-P6/A/60N | Electrical | NG32 | 350 | 500 |
(CETOP 7-8-10) NG 16-NG 25-NG 32 UNLOADING VALVE | |||||
Code | Control | Mounting | Max Pressure | Max Flow | |
CETOP 7-8-10 | Position | Norm | (bar) | (lpm) | |
RQR3-P7/1/42 | Manual | NG16 | 350 | 200 | |
RQR5-P7/1/42 | Manual | NG25 | 350 | 400 | |
RQR7-P7/1/42 | Manual | NG32 | 350 | 500 | |
RQA5-P7/1/42 | Manual | NG25 | 320 | 400 | |
RQA7-P7/1/42 | Manual | NG32 | 320 | 500 |
PRESSURE AND TEMPERATURE COMPENSATED FLOW CONTROL VALVE | |||||
Code | Control | Mounting | Max Pressure | Max Flow | Max Flow |
Position | Norm | (bar) | 1.Cycle | 3.Cycle | |
RPC1*/T/41 | Check Valve 2 way | NG6 | 320 | 0,5-1-4 | 0,5-1-4 |
RPC1*/T/41 | 2 way | NG6 | 320 | 10-16-22-30 | 10-16-22-30 |
RPC1*/CT/41 | Check Valve 2 way | NG6 | 320 | 0,5-1-4 | 0,5-1-4 |
RPC1*/CT/41 | Check Valve 2 way | NG6 | 320 | 10-16-22-30 | 10-16-22-30 |
RPC1*/CTM/41 | Check Valve 2 way | NG6 | 320 | 0,5-1-4 | - |
RPC1*/CTM/41 | Check Valve 2 way | NG6 | 320 | 10-16-22-30 | - |
RPC1*/CTX/41 | Anti jump | NG6 | 320 | 0,5-1-4 | 0,5-1-4 |
RPC1*/CTX/41 | Anti jump | NG6 | 320 | 10-16-22-30 | 10-16-22-30 |
RPC1*/T3/41 | 3 way | NG6 | 320 | 1-4-10-16-20-22 | 1-4-10-16-20-22 |
CP1RA-W10R/21 | Fast slow Roller | 3/8" | 70 | 40 | 40 |
RPC2-TN/31 | 2 way | NG16 | 320 | 22 | 22 |
RPC2-TS/31 | 2 way | NG16 | 320 | 38 | - |
RPC2-T70/31 | 2 way | NG16 | 320 | 70 | - |
RPC2-CT70/31 | Check Valve 2 way | NG16 | 320 | 70 | 70 |
RPC3-TN/43 | 2 way | NG16 | 320 | 100 | - |
RPC3-TS/43 | 2 way | NG16 | 320 | 150 | - |
RPC3-CTS/43 | Check Valve 2 way | NG25 | 320 | 150 | 150 |
RPC2-T3/31 | 3 way | NG16 | 320 | 50 | 50 |
RPC3-T3/43 | 3 way | NG25 | 250 | 150 | 150 |
RPCQ-2T3/43 | Relief Valve 3 way | NG16 | 320 | 50 | 50 |
RPCQ-3T3/43 | Relief Valve 3 way | NG25 | 250 | 150 | 150 |
EXPROOF SOLENOID PRESSURE RELIEF VALVES | ||||
Code | Description | Max Prs. (bar) | MaxFlow (lpm) | Voltage |
RQM3KD2-P6/A/M/60N-D12 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 200 | 12 V |
RQM3KD2-P6/A/M/60N-D24 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 200 | 24 V |
RQM3KD2-P6/A/M/60N-AR230 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 200 | 220 V |
RQM5KD2-P6/A/M/60N-D12 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 400 | 12 V |
RQM5KD2-P6/A/M/60N-D24 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 400 | 24 V |
RQM5KD2-P6/A/M/60N-AR230 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 400 | 220 V |
RQM7KD2-P6/A/M/60N-D12 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 500 | 12 V |
RQM7KD2-P6/A/M/60N-D24 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 500 | 24 V |
RQM7KD2-P6/A/M/60N-AR230 | EXPROOF SOLENOID Pres. Relief Valve | 350 | 500 | 220 V |
SPECIAL VALVES | ||||
Code | Description | Max Pressure(bar) | Max Flow (lpm) | |
S3-P6/20 | SEQUENCE VALVE | 35-140 | 75 | |
S5-P6/20 | SEQUENCE VALVE | 35-140 | 150 | |
U3-P6/20 | PRES. RELIEF VALVE | 35-140 | 75 | |
U5-P6/20 | PRES. RELIEF VALVE | 35-140 | 150 | |
T3-P6/20 | PRES. REDUCING VALVE | 35-140 | 75 | |
T5-P6/20 | PRES. REDUCING VALVE | 35-140 | 150 | |
X3-P6/20 | BALANCE VALVE | 35-140 | 75 | |
X5-P6/20 | BALANCE VALVE | 35-140 | 150 | |
ZC2-P5/51 | BALANCE VALVE | 50-210 | 25 | |
DZC5-210/10N | BALANCE VALVE | 0-210 | 150 | |
DZC7-210/10N | BALANCE VALVE | 0-210 | 300 | |
DZC8-210/10N | BALANCE VALVE | 0-210 | 500 |
NG16-25-32-40-50-63 LOGIC VALVE | |||||
Code | Control | Mounting | Max Pressure | Area | Max Flow |
Position | Norm | (bar) | Ratio | (lpm) | |
LC16-QS2/20N | flow control | NG 16 | 420 | 1:1,66 | 250 |
LC16-QD4/20N | flow control (Damping) | NG16 | 420 | 1:1,66 | 250 |
LC16-PS2/20N | Pressure Control | NG16 | 420 | 1:1 | 250 |
LC25-QS2/20N | flow control | NG25 | 420 | 1:1,66 | 500 |
LC25-QD4/20N | flow control (Damping) | NG25 | 420 | 1:1,66 | 500 |
LC25-PS2/20N | Pressure Control | NG25 | 420 | 1:1 | 500 |
LC32-QS2/20N | flow control | NG32 | 420 | 1:1 | 900 |
LC32-QD4/20N | flow control (Damping) | NG32 | 420 | 1:1,66 | 900 |
LC32-PS2/20N | Pressure Control | NG32 | 420 | 1:1 | 900 |
LC40-QS2/20N | flow control | NG40 | 420 | 1:1 | 1300 |
LC40-QD4/20N | flow control (Damping) | NG40 | 420 | 1:1,66 | 1300 |
LC40-PS2/20N | Pressure Control | NG40 | 420 | 1:1 | 1300 |
LC50-QS2/20N | flow control | NG50 | 420 | 1:1 | 2000 |
LC50-QD4/20N | flow control (Damping) | NG50 | 420 | 1:1,66 | 2000 |
LC50-PS2/20N | Pressure; Control | NG50 | 420 | 1:1 | 2000 |
LC63-QS2/20N | Akış Control | NG63 | 420 | 1:1,66 | 3000 |
LC63-PS2/20N | Pressure; Control | NG63 | 420 | 1:1 | 3000 |
LOGIC VALVE NORMS | |||
Code | Mounting | ||
Norm | |||
LC-16 | NG 16 | ||
LC-25 | NG 25 | ||
LC-32 | NG 32 | ||
LC-40 | NG 40 | ||
LC-50 | NG 50 | ||
LC-63 | NG 63 |
MONITORED LOGIC VALVE | |||||
Code | Control | Mounting | Max Pressure | Max Flow | |
Position | Norm | (bar) | (lpm) | ||
LCM16D1-QD4/20N | Monitored Logic Valve | ND 16 | 420 | 300 | |
LCM16D2-QD4/20N | Monitored Logic Valve | ND 16 | 420 | 300 | |
LCM16Z1-QD4/20N | Monitored Logic Valve | ND 16 | 420 | 300 | |
LCM16Z2-QD4/20N | Monitored Logic Valve | ND 16 | 420 | 300 | |
LCM25D1-QD4/20N | Monitored Logic Valve | ND 25 | 420 | 500 | |
LCM25D2-QD4/20N | Monitored Logic Valve | ND 25 | 420 | 500 | |
LCM25Z1-QD4/20N | Monitored Logic Valve | ND 25 | 420 | 500 | |
LCM25Z2-QD4/20N | Monitored Logic Valve | ND 25 | 420 | 500 | |
LCM32D1-QD4/20N | Monitored Logic Valve | ND 32 | 420 | 800 | |
LCM32D2-QD4/20N | Monitored Logic Valve | ND 32 | 420 | 800 | |
LCM32Z1-QD4/20N | Monitored Logic Valve | ND 32 | 420 | 800 | |
LCM32Z2-QD4/20N | Monitored Logic Valve | ND 32 | 420 | 800 | |
LCM40D1-QD4/20N | Monitored Logic Valve | ND 40 | 420 | 1500 | |
LCM40D2-QD4/20N | Monitored Logic Valve | ND 40 | 420 | 1500 | |
LCM40Z1-QD4/20N | Monitored Logic Valve | ND 40 | 420 | 1500 | |
LCM40Z2-QD4/20N | Monitored Logic Valve | ND 40 | 420 | 1500 |
*Pilot Valves are not included in the price.
LOGIC VALVE COVERS | ||
Code | Control | Mounting |
Position | Norm | |
LP16R/20N | NG16 COVER | ND 16 |
LP16D/20N | NG16 COVER | ND 16 |
LP16DZ/20N | NG16 COVER | ND 16 |
LP16DF1/20N | NG16 COVER | ND 16 |
LP16DF2/20N | NG16 COVER | ND 16 |
LP16Q/20N | NG16 COVER | ND 16 |
LP16DP1/20N | NG16 COVER | ND 16 |
LP16DP2/20N | NG16 COVER | ND 16 |
LP16DP3/20N | NG16 COVER | ND 16 |
LP16DP4/20N | NG16 COVER | ND 16 |
LP16DPE/20N | NG16 COVER | ND 16 |
LP25R/20N | NG25 COVER | ND 25 |
LP25D/20N | NG25 COVER | ND 25 |
LP25DZ/20N | NG25 COVER | ND 25 |
LP25DF1/20N | NG25 COVER | ND 25 |
LP25DF2/20N | NG25 COVER | ND 25 |
LP25Q/20N | NG25 COVER | ND 25 |
LP25DP1/20N | NG25 COVER | ND 25 |
LP25DP2/20N | NG25 COVER | ND 25 |
LP25DP3/20N | NG25 COVER | ND 25 |
LP25DP4/20N | NG25 COVER | ND 25 |
LP25DPE/20N | NG25 COVER | ND 25 |
LP32R/20N | NG32 COVER | ND 32 |
LP32D/20N | NG32 COVER | ND 32 |
LP32DZ/20N | NG32 COVER | ND 32 |
LP32DF1/20N | NG32 COVER | ND 32 |
LP32DF2/20N | NG32 COVER | ND 32 |
LP32Q/20N | NG32 COVER | ND 32 |
LP32DP1/20N | NG32 COVER | ND 32 |
LP32DP2/20N | NG32 COVER | ND 32 |
LP32DP3/20N | NG32 COVER | ND 32 |
LP32DP4/20N | NG32 COVER | ND 32 |
LP32DPE/20N | NG32 COVER | ND 32 |
LP40D/20N | NG40 COVER | ND 40 |
LP40DZ/20N | NG40 COVER | ND 40 |
LP40DF1/20N | NG40 COVER | ND 40 |
LP40DF2/20N | NG40 COVER | ND 40 |
LP40Q/20N | NG40 COVER | ND 40 |
LP40DP1/20N | NG40 COVER | ND 40 |
LP40DP2/20N | NG40 COVER | ND 40 |
LP40DP3/20N | NG40 COVER | ND 40 |
LP40DP4/20N | NG40 COVER | ND 40 |
LP40DPE/20N | NG40 COVER | ND 40 |
LP50D/20N | NG50 COVER | ND 50 |
LP50DZ/20N | NG50 COVER | ND 50 |
LP50DF1/20N | NG50 COVER | ND 50 |
LP50Q/20N | NG50 COVER | ND 50 |
LP50DP1/20N | NG50 COVER | ND 50 |
LP50DP2/20N | NG50 COVER | ND 50 |
LP50DP3/20N | NG50 COVER | ND 50 |
LP50DP4/20N | NG50 COVER | ND 50 |
LP50DPE/20N | NG50 COVER | ND 50 |
LP63D/20N | NG63 COVER | ND 63 |
LP63DF1/20N | NG63 COVER | ND 63 |
LP63DP1/20N | NG63 COVER | ND 63 |
LP63DP2/20N | NG63 COVER | ND 63 |
LP63DP3/20N | NG63 COVER | ND 63 |
LP63DP4/20N | NG63 COVER | ND 63 |